Enamel imitates the incisive transparency of enamel.
It is applied on top of the dentine mass. When applying the Enamel for the first time, you should focus on the adjacent teeth and restore the necessary anatomy of the restoration by 10% more than the desired result.
2nd enamel treatment: The procedure is the same as for the first firing of dentine, except for the firing temperature of 910 °C. All subsequent dentine treatments should be carried out at a temperature of 900 °C.
Dentin, Enamel, Opal, Clear, Neutral, Translucent, Modifier, Chroma, Mamelon, Gingiva
Coefficient of thermal expansion |
2 firing: 13.0 x 10-6 x K-1; 4 firing: 13,0 x 10-6 x K-1 |
Conversion temperature |
580°C ±20 |
| MC (metal ceramics) | t° preheating | Drying time | t° of the beginning of the vacuum mode | Warm-up rate | 1st firing | Exposure time |
|---|---|---|---|---|---|---|
| 1st firing
Opaque powder |
500° C | 6 min. | 500° C | 65° C / min. | 965° C | 1 min. |
| 2nd firing
Opaque powder |
500° C | 6 min. | 500° C | 65° C / min. | 965° C | 1 min. |
| 1st firing
Dentin / Enamel |
450° C | 6 min. | 450° C | 50° C / min. | 920° C | 1 min. |
| 2nd firing
Dentin / Enamel |
450° C | 6 min. | 450° C | 50° C / min. | – | – |
| Glaze | 450° C | 3 min. | – | 50° C / min. | 965° C | 1 min. |