Translucent creates special enamel pigments.
With its help, they recreate various transparency effects, color depth, or give individual features to the restoration. They are applied along the edges of the cutting edge of the crown, enhancing the effect of giving natural transparency to the enamel. When using, it is important to take into account that the mass after application must be condensed by vibrations, and excess moisture must be removed with a dry cloth.
Dentin, Enamel, Opal, Clear, Neutral, Translucent, Modifier, Chroma, Mamelon, Gingiva
Coefficient of thermal expansion |
2 firing: 13.0 x 10-6 x K-1; 4 firing: 13,0 x 10-6 x K-1 |
Conversion temperature |
580°C ±20 |
| MC (metal ceramics) | t° preheating | Drying time | t° of the beginning of the vacuum mode | Warm-up rate | 1st firing | Exposure time |
|---|---|---|---|---|---|---|
| 1st firing
Opaque powder |
500° C | 6 min. | 500° C | 65° C / min. | 965° C | 1 min. |
| 2nd firing
Opaque powder |
500° C | 6 min. | 500° C | 65° C / min. | 965° C | 1 min. |
| 1st firing
Dentin / Enamel |
450° C | 6 min. | 450° C | 50° C / min. | 920° C | 1 min. |
| 2nd firing
Dentin / Enamel |
450° C | 6 min. | 450° C | 50° C / min. | – | – |
| Glaze | 450° C | 3 min. | – | 50° C / min. | 965° C | 1 min. |